Clear Comfort CCW300A Commercial AOP System

The Clear Comfort CCW300A is a hydroxyl-based Advanced Oxidation Process supplemental sanitation system designed for entry commercial pools, splash pads, spas, therapy pools, and similar aquatic facilities.

It helps reduce chlorine demand, combined chlorine, and other disinfection by-products while supporting better water and surrounding air quality. The CCW300A works alongside the facility’s required primary sanitizer and circulation system rather than replacing them.

Why You’ll Love It

  • Designed for entry commercial pools and splash pads
  • Treats water flow rates up to 350 GPM
  • Patented hydroxyl-based AOP technology
  • Helps reduce chlorine and other chemical use
  • Helps reduce combined chlorine and disinfection by-products
  • Supports improved water and air quality
  • Proven supplemental protection against chlorine-resistant Cryptosporidium
  • Works with existing primary sanitation systems
  • Flexible inline, surge-pit, or Venturi installation options
  • Wall- or pole-mountable enclosure
  • Simple annual 15-minute cartridge exchange
  • Low 20-watt power consumption
  • NSF/ANSI 50 certified
  • UL certified
  • EPA establishment registered
  • Made in the USA
  • Five-year limited system warranty
  • Eligible for a pre-registered 90-day money-back guarantee

Commercial Supplemental Sanitation

The CCW300A is designed to supplement the facility’s required chlorine, bromine, or other approved primary sanitizer.

Clear Comfort’s AOP process generates hydroxyl radicals that oxidize contaminants introduced by swimmers and the surrounding environment.

The system can help reduce the burden placed on the primary sanitizer by addressing:

  • Organic contaminants
  • Combined chlorine
  • Chloramine-related odors
  • Oils and lotions
  • Disinfection by-products
  • Other oxidizable contaminants
  • Chlorine-resistant microorganisms

Required sanitizer residuals, filtration, turnover, testing, and operating procedures must continue to meet applicable health-code requirements.

Best Applications

The CCW300A is intended for entry-level commercial aquatic facilities, including:

  • Small commercial pools
  • Hotel and resort pools
  • Splash pads
  • Commercial spas
  • Therapy and rehabilitation pools
  • Fitness and athletic facilities
  • Apartment and multifamily pools
  • HOA pools
  • Schools and universities
  • Recreation centers
  • Boutique aquatic facilities

Final system selection should account for water flow, pool volume, turnover, bather load, operating hours, sanitizer demand, and installation configuration.

System Specifications

  • Model: CCW300A
  • Application: Entry commercial pools and splash pads
  • Technology: Hydroxyl-based Advanced Oxidation Process
  • Maximum treated water flow: 350 GPM
  • Recommended treatment-air flow: 12–14 LPM
  • Electrical supply: 120V or 240V, 60 Hz
  • Electrical rating at 120V: 1.5A
  • Electrical rating at 240V: 0.75A
  • Approximate power consumption: 20 watts
  • Current-sensor operating range: 0.25A–15A
  • Product dimensions: 25 inches high × 30 inches wide × 25 inches deep
  • Product weight: Approximately 40 lb.
  • Mounting configuration: Wall or pole mounted
  • Included power cord: 10 feet
  • Recommended ambient temperature: 40°F–90°F
  • Maximum recommended distance from injection point: 15 feet
  • Country of manufacture: USA

The CCW300A should operate only while the circulation pump is running.

Chemical and Chloramine Reduction

Clear Comfort positions its commercial AOP systems to help facilities:

  • Reduce chlorine and other chemical use by approximately 30%–50%
  • Reduce disinfection by-products by approximately 50%–90%
  • Improve combined-chlorine control
  • Improve water clarity and swimmer comfort
  • Reduce harsh chemical odors
  • Reduce chemical handling and storage demands

These are manufacturer-reported performance ranges. Actual results depend on proper system sizing, installation, chemistry, circulation, filtration, bather load, and facility operation.

Cryptosporidium Protection

Clear Comfort reports third-party university testing demonstrating a 99.99% reduction of chlorine-resistant Cryptosporidium.

The CCW300A should still be considered supplemental disinfection. Facilities must continue following all required primary-sanitation, response, testing, and health-code procedures.

Flexible Installation Options

The CCW300A can be installed using several commercial injection methods:

  • Inline diffuser rod
  • Surge-pit diffuser
  • Venturi injection
  • Air-compressor-assisted injection

The appropriate method depends on the facility’s plumbing, circulation flow, available space, surge-pit design, and hydraulic conditions.

Clear Comfort or a qualified commercial aquatic professional should review the proposed application before purchase and installation.

Inline Diffuser Installation

An inline diffuser rod may be installed in the main return plumbing after the filter and heater and before the chlorine-injection point.

A typical inline kit may include:

  • Diffuser rod
  • Air check valve
  • Air tubing
  • Air compressor enclosure
  • Flow switch
  • Junction box
  • Flow meter
  • Installation hardware

The flow switch helps prevent the system from operating without water circulation.

The CCW300A should generally be installed within 15 feet of the diffuser, with the air tubing kept as short and direct as practical.

Surge-Pit Installation

Facilities with a surge pit may introduce treated air through one or more submerged diffusers.

Diffusers should generally be positioned:

  • Near the point where water enters the surge pit
  • Away from the circulation-pump suction
  • Where bubbles can disperse effectively
  • Where the equipment remains accessible for service

Surge-pit designs vary, so the proposed installation should be reviewed before ordering the required kit.

Typical Plumbing Sequence

For an inline commercial installation, the general equipment order is:

Pool → Pump → Filter → Heater → Clear Comfort Injection Point → Chlorine Injection → Return to Pool

Chemical-feeding equipment should remain downstream of the Clear Comfort injection point unless the approved design specifies otherwise.

Air-Flow Requirements

The CCW300A requires approximately 12–14 LPM of treatment-air flow.

Correct air flow should be confirmed:

  • During installation
  • After cartridge exchange
  • After pump-speed changes
  • After plumbing changes
  • After filter service
  • When water-quality performance changes

Insufficient air flow may result from tubing restrictions, incorrect valve settings, low circulation, dirty filters, compressor issues, or improper injection placement.

System Status Indicators

The CCW300A includes front-panel status lights for monitoring system and cartridge operation.

The commercial enclosure provides access to:

  • Cartridge-status LEDs
  • System power indicator
  • Power switch
  • Door locks
  • Internal air and electrical components

Status lights should be checked during routine facility inspections.

Refer to Clear Comfort support documentation when an unfamiliar light pattern or fault condition appears.

Annual Cartridge Maintenance

Routine system maintenance consists primarily of a cartridge exchange approximately once each year.

Clear Comfort identifies this as a roughly 15-minute process that does not require lamps, special tools, or prolonged operational downtime.

The general process includes:

  1. Turn off the CCW300A
  2. Disconnect the cartridge connections
  3. Remove the air tubing
  4. Release and remove the existing cartridge
  5. Install the replacement cartridge
  6. Reconnect tubing and electrical connections
  7. Restore power
  8. Verify status lights
  9. Adjust air flow to 12–14 LPM
  10. Return the used cartridge through Clear Comfort’s exchange process

Actual replacement timing depends on operating hours and cartridge-status indicators.

Electrical Requirements

The CCW300A can operate on either 120V or 240V, 60 Hz power.

Commercial electrical installation may require:

  • GFCI-protected power
  • Proper grounding
  • Flow switch
  • Junction box
  • Air compressor
  • Current-sensor connection
  • Watertight strain reliefs and conduit
  • Control that prevents operation without circulation

The system is commonly tied to the circuit controlling pump operation or connected through a GFCI-protected outlet.

Electrical work must be completed by a qualified professional according to the unit specification label and applicable codes.

Installation Requirements

Before installation, confirm:

  • The facility falls within the CCW300A application range
  • Water flow does not exceed 350 GPM
  • Required 12–14 LPM air flow can be achieved
  • The unit can be mounted in a clean, protected area
  • The installation location remains between 40°F and 90°F
  • The unit can be placed within 15 feet of the injection point
  • Adequate wall or pole support is available
  • Proper electrical service is available
  • A suitable injection point exists after the heater
  • Chemical injection remains properly positioned downstream
  • The circulation and sanitation systems meet health-code requirements

Professional commercial installation is required.

Certifications

The CCW300A carries current manufacturer-listed certifications and registrations including:

  • NSF/ANSI 50 certification
  • UL File No. E482558
  • Canadian water-treatment equipment certification
  • EPA Establishment No. 91122-CO-3

Certification scope and installation requirements should be reviewed for each regulated facility.

Warranty

The current Clear Comfort commercial warranty provides:

  • Five-year limited warranty on the CCW300A system
  • One-year limited coverage on replacement cartridges and cylinders

Coverage applies to the original purchaser and is subject to proper registration, installation, electrical supply, operation, maintenance, and Clear Comfort’s complete terms.

Freight, removal, reinstallation, access, labor, and related costs may not be covered.

90-Day Money-Back Guarantee

The CCW300A may qualify for Clear Comfort’s 90-day money-back guarantee.

Registration is required before purchase, and additional conditions apply. The guarantee should not be represented as automatic unless the purchaser completes the required pre-purchase enrollment.

What to Confirm Before Ordering

Before ordering the CCW300A, confirm:

  1. Facility type
  2. Pool or splash-pad volume
  3. Maximum circulation flow
  4. Turnover rate
  5. Bather load
  6. Primary sanitizer
  7. Existing chemical-feed system
  8. Filtration type
  9. Heater location
  10. Available injection point
  11. Surge-pit availability
  12. Electrical supply
  13. Mounting location
  14. Injection-kit requirements
  15. Local health-code requirements
  16. Clear Comfort sizing approval

Commercial sizing and installation should be reviewed with Clear Comfort before purchase.

Frequently Asked Questions

What is the CCW300A designed for?

The CCW300A is designed for entry commercial pools, splash pads, commercial spas, therapy pools, and similar aquatic applications.

What is the maximum treated water flow?

The published maximum flow rate is 350 GPM.

Does it replace chlorine or bromine?

No. It supplements the required primary sanitizer and helps reduce the oxidation burden placed on it.

How much air flow does it require?

The recommended treatment-air flow is 12–14 LPM.

How is it installed?

The system may use an inline diffuser, surge-pit diffuser, Venturi, or air-compressor-assisted injection configuration.

How much power does it use?

The CCW300A uses approximately 20 watts.

Can it be mounted on a wall?

Yes. The CCW300A may be wall or pole mounted in a clean, protected area.

How often is the cartridge exchanged?

The cartridge is generally exchanged once annually. The process takes approximately 15 minutes.

Does it help reduce combined chlorine?

Yes. Clear Comfort positions the CCW300A to help reduce combined chlorine and other disinfection by-products when properly sized and operated.

Does Clear Comfort need to review the facility?

Yes. Commercial sizing and installation should be reviewed before ordering to confirm the correct system and injection method.

Need Help With Commercial Sizing?

Contact Summit Pool Supply for help gathering facility information and coordinating system selection with Clear Comfort.

Contact Summit Pool Supply by call or text at (866) 689-0086.

Description

Clear Comfort CCW300A Commercial AOP System

The Clear Comfort CCW300A is a hydroxyl-based Advanced Oxidation Process supplemental sanitation system designed for entry commercial pools, splash pads, spas, therapy pools, and similar aquatic facilities.

It helps reduce chlorine demand, combined chlorine, and other disinfection by-products while supporting better water and surrounding air quality. The CCW300A works alongside the facility’s required primary sanitizer and circulation system rather than replacing them.

Why You’ll Love It

  • Designed for entry commercial pools and splash pads
  • Treats water flow rates up to 350 GPM
  • Patented hydroxyl-based AOP technology
  • Helps reduce chlorine and other chemical use
  • Helps reduce combined chlorine and disinfection by-products
  • Supports improved water and air quality
  • Proven supplemental protection against chlorine-resistant Cryptosporidium
  • Works with existing primary sanitation systems
  • Flexible inline, surge-pit, or Venturi installation options
  • Wall- or pole-mountable enclosure
  • Simple annual 15-minute cartridge exchange
  • Low 20-watt power consumption
  • NSF/ANSI 50 certified
  • UL certified
  • EPA establishment registered
  • Made in the USA
  • Five-year limited system warranty
  • Eligible for a pre-registered 90-day money-back guarantee

Commercial Supplemental Sanitation

The CCW300A is designed to supplement the facility’s required chlorine, bromine, or other approved primary sanitizer.

Clear Comfort’s AOP process generates hydroxyl radicals that oxidize contaminants introduced by swimmers and the surrounding environment.

The system can help reduce the burden placed on the primary sanitizer by addressing:

  • Organic contaminants
  • Combined chlorine
  • Chloramine-related odors
  • Oils and lotions
  • Disinfection by-products
  • Other oxidizable contaminants
  • Chlorine-resistant microorganisms

Required sanitizer residuals, filtration, turnover, testing, and operating procedures must continue to meet applicable health-code requirements.

Best Applications

The CCW300A is intended for entry-level commercial aquatic facilities, including:

  • Small commercial pools
  • Hotel and resort pools
  • Splash pads
  • Commercial spas
  • Therapy and rehabilitation pools
  • Fitness and athletic facilities
  • Apartment and multifamily pools
  • HOA pools
  • Schools and universities
  • Recreation centers
  • Boutique aquatic facilities

Final system selection should account for water flow, pool volume, turnover, bather load, operating hours, sanitizer demand, and installation configuration.

System Specifications

  • Model: CCW300A
  • Application: Entry commercial pools and splash pads
  • Technology: Hydroxyl-based Advanced Oxidation Process
  • Maximum treated water flow: 350 GPM
  • Recommended treatment-air flow: 12–14 LPM
  • Electrical supply: 120V or 240V, 60 Hz
  • Electrical rating at 120V: 1.5A
  • Electrical rating at 240V: 0.75A
  • Approximate power consumption: 20 watts
  • Current-sensor operating range: 0.25A–15A
  • Product dimensions: 25 inches high × 30 inches wide × 25 inches deep
  • Product weight: Approximately 40 lb.
  • Mounting configuration: Wall or pole mounted
  • Included power cord: 10 feet
  • Recommended ambient temperature: 40°F–90°F
  • Maximum recommended distance from injection point: 15 feet
  • Country of manufacture: USA

The CCW300A should operate only while the circulation pump is running.

Chemical and Chloramine Reduction

Clear Comfort positions its commercial AOP systems to help facilities:

  • Reduce chlorine and other chemical use by approximately 30%–50%
  • Reduce disinfection by-products by approximately 50%–90%
  • Improve combined-chlorine control
  • Improve water clarity and swimmer comfort
  • Reduce harsh chemical odors
  • Reduce chemical handling and storage demands

These are manufacturer-reported performance ranges. Actual results depend on proper system sizing, installation, chemistry, circulation, filtration, bather load, and facility operation.

Cryptosporidium Protection

Clear Comfort reports third-party university testing demonstrating a 99.99% reduction of chlorine-resistant Cryptosporidium.

The CCW300A should still be considered supplemental disinfection. Facilities must continue following all required primary-sanitation, response, testing, and health-code procedures.

Flexible Installation Options

The CCW300A can be installed using several commercial injection methods:

  • Inline diffuser rod
  • Surge-pit diffuser
  • Venturi injection
  • Air-compressor-assisted injection

The appropriate method depends on the facility’s plumbing, circulation flow, available space, surge-pit design, and hydraulic conditions.

Clear Comfort or a qualified commercial aquatic professional should review the proposed application before purchase and installation.

Inline Diffuser Installation

An inline diffuser rod may be installed in the main return plumbing after the filter and heater and before the chlorine-injection point.

A typical inline kit may include:

  • Diffuser rod
  • Air check valve
  • Air tubing
  • Air compressor enclosure
  • Flow switch
  • Junction box
  • Flow meter
  • Installation hardware

The flow switch helps prevent the system from operating without water circulation.

The CCW300A should generally be installed within 15 feet of the diffuser, with the air tubing kept as short and direct as practical.

Surge-Pit Installation

Facilities with a surge pit may introduce treated air through one or more submerged diffusers.

Diffusers should generally be positioned:

  • Near the point where water enters the surge pit
  • Away from the circulation-pump suction
  • Where bubbles can disperse effectively
  • Where the equipment remains accessible for service

Surge-pit designs vary, so the proposed installation should be reviewed before ordering the required kit.

Typical Plumbing Sequence

For an inline commercial installation, the general equipment order is:

Pool → Pump → Filter → Heater → Clear Comfort Injection Point → Chlorine Injection → Return to Pool

Chemical-feeding equipment should remain downstream of the Clear Comfort injection point unless the approved design specifies otherwise.

Air-Flow Requirements

The CCW300A requires approximately 12–14 LPM of treatment-air flow.

Correct air flow should be confirmed:

  • During installation
  • After cartridge exchange
  • After pump-speed changes
  • After plumbing changes
  • After filter service
  • When water-quality performance changes

Insufficient air flow may result from tubing restrictions, incorrect valve settings, low circulation, dirty filters, compressor issues, or improper injection placement.

System Status Indicators

The CCW300A includes front-panel status lights for monitoring system and cartridge operation.

The commercial enclosure provides access to:

  • Cartridge-status LEDs
  • System power indicator
  • Power switch
  • Door locks
  • Internal air and electrical components

Status lights should be checked during routine facility inspections.

Refer to Clear Comfort support documentation when an unfamiliar light pattern or fault condition appears.

Annual Cartridge Maintenance

Routine system maintenance consists primarily of a cartridge exchange approximately once each year.

Clear Comfort identifies this as a roughly 15-minute process that does not require lamps, special tools, or prolonged operational downtime.

The general process includes:

  1. Turn off the CCW300A
  2. Disconnect the cartridge connections
  3. Remove the air tubing
  4. Release and remove the existing cartridge
  5. Install the replacement cartridge
  6. Reconnect tubing and electrical connections
  7. Restore power
  8. Verify status lights
  9. Adjust air flow to 12–14 LPM
  10. Return the used cartridge through Clear Comfort’s exchange process

Actual replacement timing depends on operating hours and cartridge-status indicators.

Electrical Requirements

The CCW300A can operate on either 120V or 240V, 60 Hz power.

Commercial electrical installation may require:

  • GFCI-protected power
  • Proper grounding
  • Flow switch
  • Junction box
  • Air compressor
  • Current-sensor connection
  • Watertight strain reliefs and conduit
  • Control that prevents operation without circulation

The system is commonly tied to the circuit controlling pump operation or connected through a GFCI-protected outlet.

Electrical work must be completed by a qualified professional according to the unit specification label and applicable codes.

Installation Requirements

Before installation, confirm:

  • The facility falls within the CCW300A application range
  • Water flow does not exceed 350 GPM
  • Required 12–14 LPM air flow can be achieved
  • The unit can be mounted in a clean, protected area
  • The installation location remains between 40°F and 90°F
  • The unit can be placed within 15 feet of the injection point
  • Adequate wall or pole support is available
  • Proper electrical service is available
  • A suitable injection point exists after the heater
  • Chemical injection remains properly positioned downstream
  • The circulation and sanitation systems meet health-code requirements

Professional commercial installation is required.

Certifications

The CCW300A carries current manufacturer-listed certifications and registrations including:

  • NSF/ANSI 50 certification
  • UL File No. E482558
  • Canadian water-treatment equipment certification
  • EPA Establishment No. 91122-CO-3

Certification scope and installation requirements should be reviewed for each regulated facility.

Warranty

The current Clear Comfort commercial warranty provides:

  • Five-year limited warranty on the CCW300A system
  • One-year limited coverage on replacement cartridges and cylinders

Coverage applies to the original purchaser and is subject to proper registration, installation, electrical supply, operation, maintenance, and Clear Comfort’s complete terms.

Freight, removal, reinstallation, access, labor, and related costs may not be covered.

90-Day Money-Back Guarantee

The CCW300A may qualify for Clear Comfort’s 90-day money-back guarantee.

Registration is required before purchase, and additional conditions apply. The guarantee should not be represented as automatic unless the purchaser completes the required pre-purchase enrollment.

What to Confirm Before Ordering

Before ordering the CCW300A, confirm:

  1. Facility type
  2. Pool or splash-pad volume
  3. Maximum circulation flow
  4. Turnover rate
  5. Bather load
  6. Primary sanitizer
  7. Existing chemical-feed system
  8. Filtration type
  9. Heater location
  10. Available injection point
  11. Surge-pit availability
  12. Electrical supply
  13. Mounting location
  14. Injection-kit requirements
  15. Local health-code requirements
  16. Clear Comfort sizing approval

Commercial sizing and installation should be reviewed with Clear Comfort before purchase.

Frequently Asked Questions

What is the CCW300A designed for?

The CCW300A is designed for entry commercial pools, splash pads, commercial spas, therapy pools, and similar aquatic applications.

What is the maximum treated water flow?

The published maximum flow rate is 350 GPM.

Does it replace chlorine or bromine?

No. It supplements the required primary sanitizer and helps reduce the oxidation burden placed on it.

How much air flow does it require?

The recommended treatment-air flow is 12–14 LPM.

How is it installed?

The system may use an inline diffuser, surge-pit diffuser, Venturi, or air-compressor-assisted injection configuration.

How much power does it use?

The CCW300A uses approximately 20 watts.

Can it be mounted on a wall?

Yes. The CCW300A may be wall or pole mounted in a clean, protected area.

How often is the cartridge exchanged?

The cartridge is generally exchanged once annually. The process takes approximately 15 minutes.

Does it help reduce combined chlorine?

Yes. Clear Comfort positions the CCW300A to help reduce combined chlorine and other disinfection by-products when properly sized and operated.

Does Clear Comfort need to review the facility?

Yes. Commercial sizing and installation should be reviewed before ordering to confirm the correct system and injection method.

Need Help With Commercial Sizing?

Contact Summit Pool Supply for help gathering facility information and coordinating system selection with Clear Comfort.

Contact Summit Pool Supply by call or text at (866) 689-0086.

Shipping

Shipping Rates and Service Area

For eligible orders shipping within the contiguous United States:

  • Orders under $100 are charged a flat $14.99 standard shipping rate.
  • Orders of $100 or more receive free standard shipping.

The $100 threshold is based on the merchandise subtotal after discounts and before taxes.

Free shipping applies to eligible standard ground and freight shipments. Certain oversized, unusually heavy, freight/LTL, or specially handled products may require an additional shipping charge. Any applicable shipping charge will be displayed at checkout whenever possible.

If a required freight charge cannot be calculated automatically, our team will contact you with a shipping quote before the order is fulfilled.

Orders shipping to Alaska or Hawaii are not eligible for the contiguous United States flat-rate or free-shipping offer. Shipping charges for these destinations will be calculated at checkout whenever possible. If a freight quote is required, our team will contact you before fulfillment.

Order Confirmation

As soon as you place your order, you will receive an order-confirmation email. This means we have received your order in our system and pre-authorized your card.

We will then confirm that the ordered item is in stock and available to ship. If an item is backordered or unavailable, we will void the pre-authorization and contact you by email to discuss the available options.

If the item is available for shipment, we will process the charge and begin preparing the order.

Handling Time

In-stock orders generally ship within three business days from the date of the order. Business days exclude weekends and holidays.

Once your order ships, we will email shipping confirmation and available tracking information to the email address provided at checkout.

Order Cutoff Time

Orders received after 1:00 p.m. Pacific Time will be treated as having been received on the following business day for handling-time purposes.

Delivery Methods and Estimated Timeframes

  • Ground shipping transit time: 1–3 business days
  • Freight/LTL transit time: 3–10 business days
  • Estimated overall delivery window, including handling and transit: 4–13 business days

Delivery estimates are not guarantees and may be affected by product availability, carrier delays, severe weather, holidays, remote delivery locations, freight appointments, or other circumstances outside our control.

Order Shipment and Tracking

Once your order ships, we will send shipping confirmation and available tracking details to the email address used at checkout.

If you have not received shipping confirmation within four business days of placing your order, please contact us at sales@summitpoolsupply.com.

Freight Deliveries

Freight and LTL deliveries may require a delivery appointment. The carrier may contact you using the telephone number provided during checkout.

Please inspect all freight shipments before signing the delivery receipt. Note any visible damage on the delivery receipt or refuse the shipment if it appears severely damaged.

Damages

Please inspect the packaging and merchandise when your order is delivered.

If you notice damage, make a note of it with the carrier at the time of delivery or refuse the shipment. If you accept delivery, immediately photograph the packaging, shipping label, and all visible product damage.

Email the photographs and your order information to sales@summitpoolsupply.com, and then visit our Returns page to submit your claim.

Keep all original packaging and materials while the damage claim is being reviewed.

Questions

Need help with an order? Contact us at sales@summitpoolsupply.com.

Why Buy From Us

We get it. You've got a lot of choice when it comes to online retailers.
Here's why we think you should shop with us at Summit Pool Supply.

Free Shipping in the USA.

30 Day Easy Returns.

Great Service. We pride ourselves on the best service, anywhere.
Your Satisfaction Guaranteed. We handpick our products for quality, we
know you'll love them. But if there is ever something wrong, we'll fix it.

CA Prop 65 Warning

⚠️ WARNING: This product can expose you to chemicals including carbon monoxide and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Description

Clear Comfort CCW300A Commercial AOP System

The Clear Comfort CCW300A is a hydroxyl-based Advanced Oxidation Process supplemental sanitation system designed for entry commercial pools, splash pads, spas, therapy pools, and similar aquatic facilities.

It helps reduce chlorine demand, combined chlorine, and other disinfection by-products while supporting better water and surrounding air quality. The CCW300A works alongside the facility’s required primary sanitizer and circulation system rather than replacing them.

Why You’ll Love It

  • Designed for entry commercial pools and splash pads
  • Treats water flow rates up to 350 GPM
  • Patented hydroxyl-based AOP technology
  • Helps reduce chlorine and other chemical use
  • Helps reduce combined chlorine and disinfection by-products
  • Supports improved water and air quality
  • Proven supplemental protection against chlorine-resistant Cryptosporidium
  • Works with existing primary sanitation systems
  • Flexible inline, surge-pit, or Venturi installation options
  • Wall- or pole-mountable enclosure
  • Simple annual 15-minute cartridge exchange
  • Low 20-watt power consumption
  • NSF/ANSI 50 certified
  • UL certified
  • EPA establishment registered
  • Made in the USA
  • Five-year limited system warranty
  • Eligible for a pre-registered 90-day money-back guarantee

Commercial Supplemental Sanitation

The CCW300A is designed to supplement the facility’s required chlorine, bromine, or other approved primary sanitizer.

Clear Comfort’s AOP process generates hydroxyl radicals that oxidize contaminants introduced by swimmers and the surrounding environment.

The system can help reduce the burden placed on the primary sanitizer by addressing:

  • Organic contaminants
  • Combined chlorine
  • Chloramine-related odors
  • Oils and lotions
  • Disinfection by-products
  • Other oxidizable contaminants
  • Chlorine-resistant microorganisms

Required sanitizer residuals, filtration, turnover, testing, and operating procedures must continue to meet applicable health-code requirements.

Best Applications

The CCW300A is intended for entry-level commercial aquatic facilities, including:

  • Small commercial pools
  • Hotel and resort pools
  • Splash pads
  • Commercial spas
  • Therapy and rehabilitation pools
  • Fitness and athletic facilities
  • Apartment and multifamily pools
  • HOA pools
  • Schools and universities
  • Recreation centers
  • Boutique aquatic facilities

Final system selection should account for water flow, pool volume, turnover, bather load, operating hours, sanitizer demand, and installation configuration.

System Specifications

  • Model: CCW300A
  • Application: Entry commercial pools and splash pads
  • Technology: Hydroxyl-based Advanced Oxidation Process
  • Maximum treated water flow: 350 GPM
  • Recommended treatment-air flow: 12–14 LPM
  • Electrical supply: 120V or 240V, 60 Hz
  • Electrical rating at 120V: 1.5A
  • Electrical rating at 240V: 0.75A
  • Approximate power consumption: 20 watts
  • Current-sensor operating range: 0.25A–15A
  • Product dimensions: 25 inches high × 30 inches wide × 25 inches deep
  • Product weight: Approximately 40 lb.
  • Mounting configuration: Wall or pole mounted
  • Included power cord: 10 feet
  • Recommended ambient temperature: 40°F–90°F
  • Maximum recommended distance from injection point: 15 feet
  • Country of manufacture: USA

The CCW300A should operate only while the circulation pump is running.

Chemical and Chloramine Reduction

Clear Comfort positions its commercial AOP systems to help facilities:

  • Reduce chlorine and other chemical use by approximately 30%–50%
  • Reduce disinfection by-products by approximately 50%–90%
  • Improve combined-chlorine control
  • Improve water clarity and swimmer comfort
  • Reduce harsh chemical odors
  • Reduce chemical handling and storage demands

These are manufacturer-reported performance ranges. Actual results depend on proper system sizing, installation, chemistry, circulation, filtration, bather load, and facility operation.

Cryptosporidium Protection

Clear Comfort reports third-party university testing demonstrating a 99.99% reduction of chlorine-resistant Cryptosporidium.

The CCW300A should still be considered supplemental disinfection. Facilities must continue following all required primary-sanitation, response, testing, and health-code procedures.

Flexible Installation Options

The CCW300A can be installed using several commercial injection methods:

  • Inline diffuser rod
  • Surge-pit diffuser
  • Venturi injection
  • Air-compressor-assisted injection

The appropriate method depends on the facility’s plumbing, circulation flow, available space, surge-pit design, and hydraulic conditions.

Clear Comfort or a qualified commercial aquatic professional should review the proposed application before purchase and installation.

Inline Diffuser Installation

An inline diffuser rod may be installed in the main return plumbing after the filter and heater and before the chlorine-injection point.

A typical inline kit may include:

  • Diffuser rod
  • Air check valve
  • Air tubing
  • Air compressor enclosure
  • Flow switch
  • Junction box
  • Flow meter
  • Installation hardware

The flow switch helps prevent the system from operating without water circulation.

The CCW300A should generally be installed within 15 feet of the diffuser, with the air tubing kept as short and direct as practical.

Surge-Pit Installation

Facilities with a surge pit may introduce treated air through one or more submerged diffusers.

Diffusers should generally be positioned:

  • Near the point where water enters the surge pit
  • Away from the circulation-pump suction
  • Where bubbles can disperse effectively
  • Where the equipment remains accessible for service

Surge-pit designs vary, so the proposed installation should be reviewed before ordering the required kit.

Typical Plumbing Sequence

For an inline commercial installation, the general equipment order is:

Pool → Pump → Filter → Heater → Clear Comfort Injection Point → Chlorine Injection → Return to Pool

Chemical-feeding equipment should remain downstream of the Clear Comfort injection point unless the approved design specifies otherwise.

Air-Flow Requirements

The CCW300A requires approximately 12–14 LPM of treatment-air flow.

Correct air flow should be confirmed:

  • During installation
  • After cartridge exchange
  • After pump-speed changes
  • After plumbing changes
  • After filter service
  • When water-quality performance changes

Insufficient air flow may result from tubing restrictions, incorrect valve settings, low circulation, dirty filters, compressor issues, or improper injection placement.

System Status Indicators

The CCW300A includes front-panel status lights for monitoring system and cartridge operation.

The commercial enclosure provides access to:

  • Cartridge-status LEDs
  • System power indicator
  • Power switch
  • Door locks
  • Internal air and electrical components

Status lights should be checked during routine facility inspections.

Refer to Clear Comfort support documentation when an unfamiliar light pattern or fault condition appears.

Annual Cartridge Maintenance

Routine system maintenance consists primarily of a cartridge exchange approximately once each year.

Clear Comfort identifies this as a roughly 15-minute process that does not require lamps, special tools, or prolonged operational downtime.

The general process includes:

  1. Turn off the CCW300A
  2. Disconnect the cartridge connections
  3. Remove the air tubing
  4. Release and remove the existing cartridge
  5. Install the replacement cartridge
  6. Reconnect tubing and electrical connections
  7. Restore power
  8. Verify status lights
  9. Adjust air flow to 12–14 LPM
  10. Return the used cartridge through Clear Comfort’s exchange process

Actual replacement timing depends on operating hours and cartridge-status indicators.

Electrical Requirements

The CCW300A can operate on either 120V or 240V, 60 Hz power.

Commercial electrical installation may require:

  • GFCI-protected power
  • Proper grounding
  • Flow switch
  • Junction box
  • Air compressor
  • Current-sensor connection
  • Watertight strain reliefs and conduit
  • Control that prevents operation without circulation

The system is commonly tied to the circuit controlling pump operation or connected through a GFCI-protected outlet.

Electrical work must be completed by a qualified professional according to the unit specification label and applicable codes.

Installation Requirements

Before installation, confirm:

  • The facility falls within the CCW300A application range
  • Water flow does not exceed 350 GPM
  • Required 12–14 LPM air flow can be achieved
  • The unit can be mounted in a clean, protected area
  • The installation location remains between 40°F and 90°F
  • The unit can be placed within 15 feet of the injection point
  • Adequate wall or pole support is available
  • Proper electrical service is available
  • A suitable injection point exists after the heater
  • Chemical injection remains properly positioned downstream
  • The circulation and sanitation systems meet health-code requirements

Professional commercial installation is required.

Certifications

The CCW300A carries current manufacturer-listed certifications and registrations including:

  • NSF/ANSI 50 certification
  • UL File No. E482558
  • Canadian water-treatment equipment certification
  • EPA Establishment No. 91122-CO-3

Certification scope and installation requirements should be reviewed for each regulated facility.

Warranty

The current Clear Comfort commercial warranty provides:

  • Five-year limited warranty on the CCW300A system
  • One-year limited coverage on replacement cartridges and cylinders

Coverage applies to the original purchaser and is subject to proper registration, installation, electrical supply, operation, maintenance, and Clear Comfort’s complete terms.

Freight, removal, reinstallation, access, labor, and related costs may not be covered.

90-Day Money-Back Guarantee

The CCW300A may qualify for Clear Comfort’s 90-day money-back guarantee.

Registration is required before purchase, and additional conditions apply. The guarantee should not be represented as automatic unless the purchaser completes the required pre-purchase enrollment.

What to Confirm Before Ordering

Before ordering the CCW300A, confirm:

  1. Facility type
  2. Pool or splash-pad volume
  3. Maximum circulation flow
  4. Turnover rate
  5. Bather load
  6. Primary sanitizer
  7. Existing chemical-feed system
  8. Filtration type
  9. Heater location
  10. Available injection point
  11. Surge-pit availability
  12. Electrical supply
  13. Mounting location
  14. Injection-kit requirements
  15. Local health-code requirements
  16. Clear Comfort sizing approval

Commercial sizing and installation should be reviewed with Clear Comfort before purchase.

Frequently Asked Questions

What is the CCW300A designed for?

The CCW300A is designed for entry commercial pools, splash pads, commercial spas, therapy pools, and similar aquatic applications.

What is the maximum treated water flow?

The published maximum flow rate is 350 GPM.

Does it replace chlorine or bromine?

No. It supplements the required primary sanitizer and helps reduce the oxidation burden placed on it.

How much air flow does it require?

The recommended treatment-air flow is 12–14 LPM.

How is it installed?

The system may use an inline diffuser, surge-pit diffuser, Venturi, or air-compressor-assisted injection configuration.

How much power does it use?

The CCW300A uses approximately 20 watts.

Can it be mounted on a wall?

Yes. The CCW300A may be wall or pole mounted in a clean, protected area.

How often is the cartridge exchanged?

The cartridge is generally exchanged once annually. The process takes approximately 15 minutes.

Does it help reduce combined chlorine?

Yes. Clear Comfort positions the CCW300A to help reduce combined chlorine and other disinfection by-products when properly sized and operated.

Does Clear Comfort need to review the facility?

Yes. Commercial sizing and installation should be reviewed before ordering to confirm the correct system and injection method.

Need Help With Commercial Sizing?

Contact Summit Pool Supply for help gathering facility information and coordinating system selection with Clear Comfort.

Contact Summit Pool Supply by call or text at (866) 689-0086.

Shipping

Shipping Rates and Service Area

For eligible orders shipping within the contiguous United States:

  • Orders under $100 are charged a flat $14.99 standard shipping rate.
  • Orders of $100 or more receive free standard shipping.

The $100 threshold is based on the merchandise subtotal after discounts and before taxes.

Free shipping applies to eligible standard ground and freight shipments. Certain oversized, unusually heavy, freight/LTL, or specially handled products may require an additional shipping charge. Any applicable shipping charge will be displayed at checkout whenever possible.

If a required freight charge cannot be calculated automatically, our team will contact you with a shipping quote before the order is fulfilled.

Orders shipping to Alaska or Hawaii are not eligible for the contiguous United States flat-rate or free-shipping offer. Shipping charges for these destinations will be calculated at checkout whenever possible. If a freight quote is required, our team will contact you before fulfillment.

Order Confirmation

As soon as you place your order, you will receive an order-confirmation email. This means we have received your order in our system and pre-authorized your card.

We will then confirm that the ordered item is in stock and available to ship. If an item is backordered or unavailable, we will void the pre-authorization and contact you by email to discuss the available options.

If the item is available for shipment, we will process the charge and begin preparing the order.

Handling Time

In-stock orders generally ship within three business days from the date of the order. Business days exclude weekends and holidays.

Once your order ships, we will email shipping confirmation and available tracking information to the email address provided at checkout.

Order Cutoff Time

Orders received after 1:00 p.m. Pacific Time will be treated as having been received on the following business day for handling-time purposes.

Delivery Methods and Estimated Timeframes

  • Ground shipping transit time: 1–3 business days
  • Freight/LTL transit time: 3–10 business days
  • Estimated overall delivery window, including handling and transit: 4–13 business days

Delivery estimates are not guarantees and may be affected by product availability, carrier delays, severe weather, holidays, remote delivery locations, freight appointments, or other circumstances outside our control.

Order Shipment and Tracking

Once your order ships, we will send shipping confirmation and available tracking details to the email address used at checkout.

If you have not received shipping confirmation within four business days of placing your order, please contact us at sales@summitpoolsupply.com.

Freight Deliveries

Freight and LTL deliveries may require a delivery appointment. The carrier may contact you using the telephone number provided during checkout.

Please inspect all freight shipments before signing the delivery receipt. Note any visible damage on the delivery receipt or refuse the shipment if it appears severely damaged.

Damages

Please inspect the packaging and merchandise when your order is delivered.

If you notice damage, make a note of it with the carrier at the time of delivery or refuse the shipment. If you accept delivery, immediately photograph the packaging, shipping label, and all visible product damage.

Email the photographs and your order information to sales@summitpoolsupply.com, and then visit our Returns page to submit your claim.

Keep all original packaging and materials while the damage claim is being reviewed.

Questions

Need help with an order? Contact us at sales@summitpoolsupply.com.

Why Buy From Us

We get it. You've got a lot of choice when it comes to online retailers.
Here's why we think you should shop with us at Summit Pool Supply.

Free Shipping in the USA.

30 Day Easy Returns.

Great Service. We pride ourselves on the best service, anywhere.
Your Satisfaction Guaranteed. We handpick our products for quality, we
know you'll love them. But if there is ever something wrong, we'll fix it.

CA Prop 65 Warning

⚠️ WARNING: This product can expose you to chemicals including carbon monoxide and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.